{"id":2508,"date":"2020-11-03T15:49:55","date_gmt":"2020-11-03T15:49:55","guid":{"rendered":"https:\/\/valdorsac.com\/?post_type=astra-portfolio&#038;p=2508"},"modified":"2021-05-23T21:56:33","modified_gmt":"2021-05-23T21:56:33","slug":"resistividad-electrica-y-polarizacion-inducida","status":"publish","type":"astra-portfolio","link":"https:\/\/valdorsac.com\/en\/met\/resistividad-electrica-y-polarizacion-inducida\/","title":{"rendered":"ELECTRICAL RESISTIVITY AND INDUCED POLARIZATION"},"content":{"rendered":"<h1 class=\"has-black-color has-text-color wp-block-heading\"><strong>ELECTRICAL RESISTIVITY AND INDUCED POLARIZATION<\/strong><\/h1>\n\n\n\n<div style=\"height:46px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-justify wp-block-paragraph\">The electrical resistivity method investigates horizontal and vertical discontinuities in the electrical properties of the subsurface, as well as the detection of anomalous electrical conductivity bodies. Induced polarization is measured in conjunction with electrical resistivity and is mainly used in the detection of disseminated ore zones by measuring the capacitive behavior of the subsurface in the presence of an induced current.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"628\" src=\"https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_RES3-1024x628.png\" alt=\"\" class=\"wp-image-3300\" srcset=\"https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_RES3-1024x628.png 1024w, https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_RES3-300x184.png 300w, https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_RES3-768x471.png 768w, https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_RES3.png 1130w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-justify wp-block-paragraph\">The method acquisition consists of placing conductive rods (electrodes) in the ground. The electrodes can be of two types: current transmitting and potential receiving. Transmitting electrodes inject electric current into the ground while receiving electrodes measure the potential difference between the equipotentials generated by current induction. The different configurations and distances between electrodes allow obtaining appropriate results to the survey scope, which may vary in the acquisition horizontal and\/or vertical resolution, depth of investigation, predominant rock in the survey area and the time available to complete the acquisition.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_IP3-1-1024x623.png\" alt=\"\" class=\"wp-image-3308\" width=\"493\" height=\"300\" srcset=\"https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_IP3-1-1024x623.png 1024w, https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_IP3-1-300x183.png 300w, https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_IP3-1-768x467.png 768w, https:\/\/valdorsac.com\/wp-content\/uploads\/2021\/05\/IMAGEN_METODO_IP3-1.png 1104w\" sizes=\"(max-width: 493px) 100vw, 493px\" \/><\/figure><\/div>\n\n\n\n<p class=\"has-text-align-justify wp-block-paragraph\">Through the data analysis, 2D\/3D modeling and resistivity and chargeability anomalies interpretation, the electrical resistivity and induced polarization method allows the detection of disseminated sulfide concentrations of metallic luster (porphyry copper, veins or structures with gold content, etc.).<\/p>\n\n\n\n<p class=\"has-text-align-justify wp-block-paragraph\">Additionally, the method is also useful in the detection of contacts and structures based on the resistivity contrasts of conductive and resistive units as well as the detection of disseminated or longitudinal sulfides, surrounding a semi-massive deposit. The resistivity and induced polarization method can also be used in the mapping of alteration zones and structural ore deposit control (porphyry copper systems).<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-black-color has-luminous-vivid-amber-background-color has-text-color has-background no-border-radius\" rel=\"https:\/\/valdorsac.com\/contactanos\/\">Contact Us<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"featured_media":2761,"template":"","meta":{"_editorskit_title_hidden":false,"_editorskit_reading_time":0,"_editorskit_is_block_options_detached":false,"_editorskit_block_options_position":"{}","site-sidebar-layout":"default","site-content-layout":"boxed-container","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"disabled","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"astra-portfolio-categories":[104,103],"astra-portfolio-other-categories":[],"astra-portfolio-tags":[],"class_list":["post-2508","astra-portfolio","type-astra-portfolio","status-publish","has-post-thumbnail","hentry","astra-portfolio-categories-geotecnia","astra-portfolio-categories-mineria"],"astra-site-call-to-action":"","astra-site-open-in-new-tab":0,"astra-site-open-portfolio-in":"same-tab","astra-site-url":"","thumbnail-image-url":"https:\/\/valdorsac.com\/wp-content\/uploads\/2020\/11\/FOTO_METODO_RES_IP.jpg","thumbnail-image-meta":{"alt":"","title":"FOTO_METODO_RES_IP"},"lightbox-image-url":null,"portfolio-type":"page","portfolio-video-url":"","request_time":0.0700190067291259765625,"_links":{"self":[{"href":"https:\/\/valdorsac.com\/en\/wp-json\/wp\/v2\/astra-portfolio\/2508","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valdorsac.com\/en\/wp-json\/wp\/v2\/astra-portfolio"}],"about":[{"href":"https:\/\/valdorsac.com\/en\/wp-json\/wp\/v2\/types\/astra-portfolio"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/valdorsac.com\/en\/wp-json\/wp\/v2\/media\/2761"}],"wp:attachment":[{"href":"https:\/\/valdorsac.com\/en\/wp-json\/wp\/v2\/media?parent=2508"}],"wp:term":[{"taxonomy":"astra-portfolio-categories","embeddable":true,"href":"https:\/\/valdorsac.com\/en\/wp-json\/wp\/v2\/astra-portfolio-categories?post=2508"},{"taxonomy":"astra-portfolio-other-categories","embeddable":true,"href":"https:\/\/valdorsac.com\/en\/wp-json\/wp\/v2\/astra-portfolio-other-categories?post=2508"},{"taxonomy":"astra-portfolio-tags","embeddable":true,"href":"https:\/\/valdorsac.com\/en\/wp-json\/wp\/v2\/astra-portfolio-tags?post=2508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}